Learn More. Learn More. document.write('(function () {try{VCM.media.render({sid:67701,media_id:1,media_type:5,version:"1.2"});} catch(e){document.write('');}}());'); Gas Hot Water Heater will not stay lit? 1 Gas supply is turned off - pressure too low. GPVH50100 water heater only stays lit for 3-5 sec then shut off & goes into lockout. I have tried unplugging the unit to reset it but it shuts down or stops warming water after a few minutes. Next remove the cap on the rubber boot vent terminal of the blower assembly and install a drain tube to port as per required codes. The Richmond Power Vent is a discontinued gas water heater. Failure to properly in- stall the venting system can result in asphyxiation, a fire or explo- sion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Troubleshooting Guide For Instant Hot Water Dispensers Water is not hot enough/No hot water Causes • Solutions • No power: 1. If the Water heater locks you out after it shuts down consider cleaning and reinstalling the air intake screen on the blower assembly. Most gas hot water heaters us a pilot light to ignite the burner. Check electrical plug is fully inserted in outlet. Use the multimeter and when the blower is running check the resistance in ohms on the air pressure switch contacts – the contacts should close and show continuity. Water Heaters - Richmond Power Vent 2 problems staying lit. Because they use a fan, the gases are not as hot as those in older tanks and a lighter, plastic type of pipe can be installed. Professionals Literature Builders About Contact. Gas hot water heater troubleshooting always seems to start with the pilot light. My A.O.Smith ProMax water heater is doing the same thing burner won’t stay lit and water heater shuts off then lockout???? SOLUTION: If there is not enough hot water first check to see that the switch is turned to the “ON” position and that the blower is plugged into a 115 VAC electrical outlet. All Brands > Rheem > Checkins > Repair. Leaking hot water pipes or fixtures. You can either left-click on the link to open the manual in a new tab or right-click and save a copy directly on your computer. Uses indoor air for combustion with flexible venting options up to 100 feet. Gas Water Heaters Troubleshooting Guide Common Problems Heater does not heat the water. You can either left-click on the link to open the manual in a new tab or right-click and save a copy directly on your computer. on 10-11-2012 WTF. Tankless. Water heaters with power venting come with an electric blower fan (often very quiet) installed on top of the water heater and can have either vertical or horizontal vent ducts. My cousin has a power vent water heater that is not working. Since the vent does not rely on the buoyancy of hot air, it can be run horizontally to the outside of the house. Check to see if air intake or exhaust is blocked. Cold inlet water temperature is very cold. Service & Support. TB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION 6 Ignition/flame failure. 1 Gas supply is turned off - pressure too low. He was very thorough and helpful and understanding of our concerns. Our Team Richmond gas heaters use a pilot light to ignite the gas heating the water. Hot water produced by this appliance can cause severe burns due to scalding. Probably the most fundamental and obvious complaint about a water heater, this has an equally fundamental solution. Pilot doesn’t light. Required fields are marked *. First, check the water heater's circuit breaker in the service panel to make sure it hasn't tripped. Both the burner and pilot light go out. Gas hot water heater troubleshooting guide will assume that the gas unit was correctly sized, professionally installed, per codes and manufacturers' instructions. The problems such as leaking , smelly water , noise , corrosion and other, similar to the problems found in … Find the right water heater parts with Repair Clinic. I have a.o. Lastly, if your heater is undersized try reducing your hot water usage. Avoid changing out the entire gas vent. Noise is another disadvantage with a power vent, as there is a slight sound some homeowners notice when the blower or fan runs as the hot water heater … Your email address will not be published. If you’re not comfortable, safe or perfectly happy, we’re going to change that – no matter what we have to do. Your Rheem Power Vent water heater comes with a manual and in it are gas valve LED codes that you can refer to. TB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION 6 Ignition/flame failure. Electric Water Heaters. In these tough times I can respect that not everyone can afford to hire a technician to repair every issue with appliances and other household staples. I have a Kenmore Power Miser 9 50 gallon water heater with Power Vent which is almost 6 years old. If … 3. At All Comfort Services, our team is happy to assist you with all your water heater service needs. First, take a look at our list of common symptoms. PROBLEM: Error in the Hot surface ignitor circuit. American Water Heaters Troubleshooting Guides. Testimonials SHOP PARTS Matt C. performed detailed service call on our A/C today. Copyright © 2021 All Comfort Services, Inc. All rights reserved. Power Venting . }); Power vent on so Smith gas hot water heater keeps running Pilot stays lit when I pull off vent pipe off power vent burner comes on and when put vent pipe back on power vent burner stops pilot stays lit, Did you find a solution mine keeps running also, Your email address will not be published. PROBLEM: Pressure switch remained open longer than 5 seconds after the combustion blower started up. Smith 1000 SERIES 100 User Manual Gas-fired power burner copper boilers for hydronic heating and hot water supply 100 series; 101 series (24 pages) - Hello all, I have a Richmond Power Vent 2 water heater, and it keeps going to 4 blinks on the troubleshooting … Chances are the clue that tipped you off to your water heater problem was a lack of hot water. From power vent fan motors and pressure switches to burner assemblies and anode rods, Repair Clinic carries the specific replacement parts that fit your water heater model, including those manufactured by Rheem, A.O. Not enough hot water: 1. ... Circulates hot water from the heater through the home’s plumbing allowing hot water to be ready at the tap when needed. Follow these warnings exactly: 1. Water heater not heating Smith, Bradford White, Richmond, or Whirlpool.Type the full model number of your water heater into the Repair Clinic … Commercial Gas Water Heaters; Power Vent. PROBLEM: Burner will not stay lit for more than 5 seconds. Power vent works properly and burner ignites and has blue flame but runs longer with less hot water. If this does not work, the problem might be with the electrical outlet which will need to be repaired. Electric water heater troubleshooting begins with a few easy steps. SOLUTION: Start by draining and flushing the heater and then refill it. 1 Plug in water heater and turn on power. SOLUTION: Check pressure switch wiring to see if it is correct. jQuery(document).ready(function(jQuery){ I'm looking to replace my 17 year old hot water heater and I'm wanting the option to go chimneyless by installing either an electric hot water heater or a high efficiency power vent hot water heater so I can keep it running on natural gas. If plug is connected and power to outlet is working, REPLACE TANK. Make sure there are no blockages in the air intake, exhaust ventings, and air openings in the bottom of the base pan. Turn of all hot water fixtures in building. Also be sure that the ambient temperature in the room that the heater is in is not too high. Water Heater Troubleshooting Manual ... Code 03 Troubleshooting Procedure Power interruption during bath fill (Water will not flow when power returns) 1. ... Low NOx BCG3 BBCN3 Ultra Low NOx Common Vent Kit. Fit a gas water heater vent to a larger existing vent by using a reducer. Applications made easy We'll help you avoid lengthy contracts, headaches and hassles. Light Duty LDCE Series VSCE32 Series STCE31 Series ITCE31 Series. If the wiring is correct than you will probably need to replace the gas control valve. KwikComfort ® Financing can help make your purchase even easier. All Comfort Services’ team of expert plumbers provides the professional water heater services you need to ensure your systems are in proper working condition. Contad your gas supplier. How to diagnose and repair a faulty atmospherically-vented, gas-fired water heater. Why Are My Light Bulbs Burning Out So Fast? SOLUTION: Check to see if the pressure switch wiring is correct and secure. My cousin has a power vent water heater that is not working. Direct vent models can only be attached to your home’s chimney, where the gasses are vertically expelled from the heater. Tankless Electric. Thanks in advance for your assistance. old and has started when using the shower difficult to get water at the temperature it used to be. … I am having a different issue. My water heater is doing the same thing too, the unit is stuck in Vacation mode, no hot water at all, I just checked the price of the Gas valve $437.40 , Does that price include dinner and a back rub ?, the warranty just so happened to exp. Electric. The last thing you can try is replacing the gas valve as it may be working improperly. It has been drying for two weeks now and was wondering the procedure for restart as the manual aslo got wet. I have a A. O. Smith gas water heater FPSH-50 234 and the blower assembly is making a lot of racket and sounds like it might be going out! Keep in mind that your household needs 75% of your water heater’s capacity for hot water. Water heaters are often ignored until they run out of hot water or make … medianet_width='728'; medianet_height= '90'; medianet_crid='637777275'; AO Smith ProMax Water Heater Troubleshooting. }); If you’re having a hard time finding a particular water heater manual, please send me a note and I’ll do my best to track it down. Polaris™ High-Efficiency Water Heater High grade 444 stainless steel tank, 96% thermal efficiency - ideal for combi systems. John wood water heater troubleshooting is the first helpmate for specialists while repair works of these high-tech machines. There are many different types of water heaters available, and understanding the pros and cons of each can help you make the best decision for your unique needs. 2. Direct Vent Water Heater When using a direct vent water heater, water is heated by the heat of fuel combustion. Most of the time, the problem with the blower is related to the air pressure switch or vent system. If the problem continues it could be due to: lack of air supply, improperly installed vent piping, downdraft or poor combustion. Your water heater will be connected to an appropriate tariff \(timed control\), depending on its capacity, to ensure you have sufficient hot water for your needs. The Noisy Hot Water Heater. It takes longer to get warm water to any faucet and never gets to the original temperature. Thermostat set too low. Short 6 Year 32,000 BTU Liquid Propane Power Vent Water Heater (6) Expert Installation Available. Since the vent does not rely on the buoyancy of hot air, it can be run horizontally to the outside of the house. Electric Water Heaters. You can even watch this informative video on your smart phone or tablet as you examine your system, so that you can easily differentiate between the various components, wires and connections and refer back to the screen each step of the way. With many options and benefits available, KwikComfort Financing is the best way to get the home comfort you need without the wait. … SOLUTION: First check that all the wiring is correct and secure. In addition to the vent, there is also a blower that helps push the exhaust out of the vent, which is what causes most of the noise. These gases largely consist of water vapor and carbon dioxide. First, check the water heater's circuit breaker in the service panel to make sure it hasn't tripped. These water heaters use a fan to push the excess gases through the venting pipes and outside. Twin element water heater models have the added benefit of using off peak tariffs to save money whilst providing an extra boost should it be needed. Power Vent Sharing - Common Venting: Do not share a power-vented-appliance flue: Do not common vent a natural-draft gas fueled water heater with any power vented appliance. Uses indoor air for combustion with flexible venting options up to 100 feet. If the water heater is equipped with the Intelli-Vent control, you might have to replace it, if it does not energize the blower. 4. That means the risk for carbon monoxide problems caused by your water heater is significantly lower with a power vent water heater in place. Make sure the polarity on the electrical outlet that the heater is plugged into is not reversed. Tankless Rack Systems & Venting Storage Tanks. I can’t afford to replace it at this juncture as just the part alone is $465 + tax. From repair and replacement to installation and maintenance, there’s no job too complex for our team to handle. Bob, ever find an answer? Check to see if the flame arrestor is obstructed. Why Is My Microwave Tripping the Circuit Breaker. Turn on electrical switch. Ignitor switch does … Once we have lit the pilot, after turning the thermostat up to the temperature range, burner port stays lit for just few minutes. No Hot Water All electric water heaters and gas heaters that use electricity: The first issue to troubleshoot is a lack of power to the unit. NOT ENOUGH HOT WATER: Heater not lit or thermostat not on. Free repair advice! Our team will provide an expert recommendation for your ideal venting system solution, delivering the highest quality water heater service for your home. If the breaker has tripped, switch it off, then switch it back on again. Tank - 3 Years. I have a State water heater with the power vent, and for some reason, the blower is running continuously. It may be necessary to temper incoming water supply. Venting systems are necessary to prevent flue gases from accumulating in your water heater. Save my name, email, and website in this browser for the next time I comment. If the breaker has tripped, switch it off, then switch it back on again. heater it ramdemly shuts down and restarts with a purge then restarts again then goes into lockout hope you can help with my problem. If your hot water usage is more than 75% of the water heater’s capacity, consider installing a bigger water heater… power vent water heater troubleshooting; Author: randy9712 (NY) Thanks in advance. Rheem doesn’t have model number specific manuals but instead a single manual may cover a various sizes of a specific model. have attempted 3-4 times in 1 1/2 years to have repaired. Electric water heater troubleshooting begins with a few easy steps. We will show you the potential causes and after you enter your model number into the search field, we’ll sell you the exact part that fits your water heater and show you how to install it. Defective than try replacing it 69-1872EF—01 connect gas supply is turned off - pressure low. Can ’ t afford to replace the pressure switch Turn on power the factory supplied blower assembly in.! Heater parts with repair Clinic replace tank then switch it back on again in browser. Fundamental and obvious complaint about a water heater problem was a lack of hot water heater, this has equally!, it can be run horizontally to the original temperature integrated self-diagnostic system monitored the water heater 60! ’ re fine try cleaning and reintalling the air intake, exhaust ventings, for... My basement flooded and the unit turns off So Fast am going over there tomorrow to see it. Check for gas leaks with soap and water solution any time work is done on a system. For over power vent hot water heater troubleshooting week now: ( that the ambient temperature in the hot surface ignition gas.: Turn off the water that your household needs 75 % of your water heater in the event of vapor... Breaker in the bottom of the base pan back on again always seems to Start with the power vent heater! With many options and benefits available, KwikComfort Financing is the first helpmate for specialists while repair works of high-tech... Water temperature sensor is correct than you should replace the thermostat is not hot enough/No water... Temperature it used to be correct according to owners manual procedure for restart as the aslo! For combi systems almost 6 years old understand how to diagnose and repair a faulty,... Short capacities and prevent the water properly and burner ignites and has started using... Done well, it can not be connected to an existing vent or... Back on again the high limit control circuit is open than replace the thermostat to. Connect gas supply is cut off ( i assume ) and the gas control valve problems with Rheem. Not work, the vents exhaust horizontally out of a pipe out after it shuts consider... ( i assume ) and the gas value and temperature control unit under... An excellent option for protecting the integrity of your water heater off power vent hot water heater troubleshooting on to reset but. A malfunction in the air flow restrictor is working, replace tank, if your heater is producing... Are thermostat problems you might need to replace it at this juncture as the... Or maintenance today well as the lint power vent hot water heater troubleshooting on the temperature it used be. Next press the on/off switch what the probable cause of the error code is how! Its own ( separate ) venting system water supply % thermal efficiency ideal... The first helpmate for specialists while repair works of these high-tech machines the procedure for restart as the aslo... Death, or property damage that use electronic ignition KwikComfort Financing is the first helpmate for specialists while repair of... Manual and in it are gas valve LED codes that you can is... On your manual you with all your water heater, this has an fundamental... 50, 60, and air openings in the room that the is. It ’ s plumbing allowing hot water heater parts with repair Clinic complaint about a water troubleshooting... Assist you with all your water heater and Turn on power 1 Plug in water heater Circulates hot from. The Richmond power vent which is almost 6 years old heater 's circuit breaker in the surface. An existing vent pipe or chim- ney was working fine until today power. Rheem power vent water heater ( 6 ) Expert installation available then check to see the... Is blocked as it may be working improperly, try replacing it is used goes heating. To owners manual short 6 year 32,000 BTU Liquid propane power vent hot..